Free cookie consent management tool by TermsFeed Policy Generator

Sunlight-Readable Industrial Displays: Optical Bonding, Transflective LCDs and Long-Term Availability Explained

A display that looks perfect in the lab can become a grey mirror in the sun. On a construction machine, an agricultural vehicle, a charging station or a ship's bridge, operators suddenly see their own reflection instead of the user interface. The common reaction is to ask for a brighter display. But brightness alone rarely solves the problem, and it creates new ones: heat, power consumption and shorter backlight lifetime.

This article explains what really makes an industrial display readable in sunlight, why optical bonding is often more effective than more brightness, when a transflective LCD is the better choice, and how to make sure the display you choose today is still available in ten years. For an overview of our options, see our industrial display solutions.

Sunlight readability in 60 seconds

  • Contrast, not brightness, is the key. Sunlight adds reflected light to black and white areas alike and washes out the image.
  • Every air-glass interface reflects about 4 % of the incoming light. A display with an air gap between cover glass and LCD has several such interfaces.
  • Optical bonding fills the air gap with a transparent material, removes these internal reflections and can improve sunlight contrast many times over.
  • High brightness of around 800–1,000 cd/m² and more helps, but costs power and creates heat.
  • Transflective LCDs use sunlight itself to light the image and stay readable with low power.
  • Long-term availability must be planned from the start, especially now that several manufacturers are leaving the industrial LCD market.

 

Why displays become unreadable in sunlight

Direct sunlight can reach around 100,000 lux, many times the lighting in an office. Part of this light is reflected by the display surface and by every internal layer. The reflected light adds to both the bright and the dark pixels. The result: black turns grey, colours fade and the contrast collapses.

The decisive value is therefore the ambient contrast ratio: the brightness of a white pixel plus reflections, divided by the brightness of a black pixel plus reflections. As a rule of thumb from display engineering, full-colour graphics need an ambient contrast of around 7:1, simple dark text on a light background around 3:1.

There are two ways to improve this ratio: increase the light the display emits, or reduce the light it reflects. The second way is usually more efficient.

Optical bonding: removing reflections at the source

The problem with the air gap

In a conventional display assembly, a cover glass or touch sensor sits in front of the LCD with a thin air gap in between. Each transition between air and glass, or air and polariser, reflects roughly 4 % of the incoming light. Together, these internal reflections can exceed the light the display itself emits in bright sunlight.

How optical bonding works

Optical bonding fills the air gap with a transparent material whose refractive index is close to that of glass. Typical materials are silicone gels, optically clear adhesive films and liquid optically clear adhesives or resins. Because the refractive index barely changes from layer to layer, the internal reflections almost disappear.

The effect can be dramatic. In a widely cited example from a display manufacturer, the reflected glare of a display in strong sunlight dropped from more than 4,000 cd/m² to about 240 cd/m² after optical bonding combined with an anti-reflective coating. The calculated sunlight contrast rose from about 1.3:1, practically unreadable, to about 7:1, at the same backlight brightness.

Further benefits of optical bonding

  • No condensation or dust between cover glass and display, because there is no air gap left.
  • Higher mechanical robustness: the bonded stack supports the cover glass and improves impact resistance.
  • Less parallax: the image appears closer to the touch surface, which makes touch input more precise.
  • Better touch performance: a stable, bonded stack-up helps capacitive touch controllers work reliably.

Limits

Optical bonding increases the cost of the display assembly and must be done in a controlled process. Depending on the material, rework is difficult or impossible: silicone-based bonding can often be reworked, rigid adhesives usually cannot. The bonding material must also be qualified for the temperature range of the application.

High brightness: useful, but not free

Standard office displays have a brightness of around 250 to 350 cd/m². Displays for outdoor use often start at around 800 to 1,000 cd/m² and go higher. More brightness definitely helps, but it comes with consequences:

  • Power consumption rises considerably, which matters for battery-powered and vehicle applications.
  • Heat builds up behind the display and must be dissipated, especially in sealed housings.
  • Backlight lifetime can drop when LEDs are driven at high current and high temperature.
  • At night, a very bright display can blind the operator. An ambient light sensor with automatic dimming is therefore part of a good design.

Best practice: combine optical bonding and anti-reflective or anti-glare surfaces with a moderately increased brightness. This usually achieves better readability with lower power and heat than brightness alone.

Transmissive, transflective, reflective: which display technology?

TechnologyHow it worksStrengthsLimits
Transmissive (standard TFT)Backlight shines through the LCDBrilliant colours indoors, wide choice of sizes and suppliersNeeds high brightness and bonding for sunlight
TransflectiveUses backlight indoors and reflects ambient light outdoorsReadability improves as sunlight gets stronger; low powerFewer sizes and suppliers; colours less saturated than high-end transmissive displays
Reflective (e.g. Memory-in-Pixel)Uses only ambient light, optionally a front lightExtremely low power, excellent in daylightLimited colours and refresh rate; needs light to be readable

 

Transflective LCDs are a strong option for devices used mainly outdoors, battery-powered equipment and applications where power and heat must be kept low. For colour-rich user interfaces that are used both indoors and outdoors, a bonded high-brightness transmissive display is often the more flexible solution.

Surfaces and cover glass

  • Anti-reflective (AR) coatings reduce reflections on the outer surface of the cover glass.
  • Anti-glare (AG) surfaces scatter reflections so that light sources no longer appear as sharp mirror images.
  • Chemically strengthened cover glass improves impact resistance for public and industrial environments.
  • Polariser choice matters: operators wearing polarised sunglasses may see a dark display if the polariser orientation is not considered.

If the display also has a touch function, the choice of touch technology affects readability. Our comparison of capacitive and resistive touchscreens explains the differences.

Long-term availability: the often forgotten requirement

Sunlight-readable displays are typically used in products with long lifecycles: machines, vehicles, medical devices and infrastructure. A display that is discontinued after a few years forces a redesign, new tests and sometimes new approvals.

This risk is real: several manufacturers have announced their exit from industrial LCD production. Our article on what to do when an industrial LCD is discontinued explains the current situation and the replacement options.

How to reduce the risk from the start:

  1. Choose displays from suppliers with documented long-term availability.
  2. Prefer standard sizes and standard interfaces such as LVDS or eDP, which make later replacement easier.
  3. Document the complete optical stack: display, bonding material, cover glass, coatings and touch.
  4. Monitor product change and end-of-life notices actively.
  5. Plan a replacement strategy before the first discontinuation notice arrives.

Checklist: specifying a sunlight-readable display

Answer these questions before requesting a display

  • Where is the display used: fully outdoors, in vehicles, behind windows, indoors and outdoors?
  • Which content must be readable: colour graphics, text, video, maps?
  • From which angles and distances do operators look at the display?
  • Is power limited, for example by a battery?
  • Which temperature range and enclosure protection are required?
  • Is touch needed, and will operators wear gloves or polarised sunglasses?
  • How many years must the display remain available?

 

How T&O Electronic Solutions helps

T&O Electronic Solutions develops and builds customised display and HMI solutions in Hausham, Germany. Our display solutions include:

  • Sunlight-readable and high-brightness displays for demanding environments, as described in our article on military technology displays
  • Optical bonding to reduce reflections and improve robustness
  • Anti-glare glass, anti-reflective coatings and custom cover glass, including chemically strengthened glass
  • PCAP touch for operation with gloves and in demanding environments
  • Long-term product availability and proactive obsolescence management

If a display in your existing product is affected by a discontinuation, use our free obsolescence check.

Frequently asked questions

What makes a display sunlight-readable?

A sunlight-readable display keeps enough contrast in bright ambient light. This is achieved by reducing reflections, for example with optical bonding and anti-reflective surfaces, combined with sufficient brightness or a transflective display technology.

How bright must a display be to be readable in sunlight?

There is no single value. Displays for outdoor use often start at around 800 to 1,000 cd/m². With optical bonding and anti-reflective surfaces, less brightness is needed for the same readability than without them.

What is optical bonding?

Optical bonding fills the air gap between the cover glass or touch sensor and the LCD with a transparent material. This removes internal reflections, prevents condensation and dust, and makes the display assembly more robust.

Can optical bonding be repaired or reworked?

It depends on the material. Silicone-based bonding can often be reworked; rigid adhesives usually cannot. Clarify the repair concept before choosing the bonding process.

What is the difference between transmissive and transflective displays?

A transmissive display creates its image only with the backlight. A transflective display also reflects ambient light, so it becomes more readable in strong sunlight and needs less power outdoors.

Is a transflective display always better outdoors?

Not always. Transflective displays are efficient and readable in sunlight, but the choice of sizes is smaller and colours are less saturated. For colour-rich interfaces used indoors and outdoors, a bonded high-brightness display is often more flexible.

Why does my display turn dark with sunglasses?

LCDs emit polarised light. If the polariser orientation of the display and of polarised sunglasses are crossed, the display can appear dark. This can be avoided by choosing the right polariser orientation or special polariser films.

How can we secure long-term availability for our display?

Choose suppliers with long-term availability commitments, use standard interfaces, document the full optical stack and monitor discontinuation notices. If a display is discontinued, act early to qualify a replacement.

Would you like to receive a free callback?